C Purlin Span Table

2 mm BMT Grade AS1397/G500 Z350 - Fy = 500 Mpa. A flat roof rafter to span 12 ft could be 2x8 #2 24" O-C and meet code by me. In order to furnish a review of the completed tests, the schematic test set-up is shown in Fig. Purlin Load Tables. By Table 20: If X 12, 2x10, 3x10, 4x8. Steeline C Purlins are available in different sizes and material strengths to match the design specification of your building. 01 Kn/m (with one. galvanize c purlins 2″ x 6″ x 6 meters @ 600. B Fixed every purlin on every rib with approved screws and neos and alloy embossed washers C Fixed every purlin on every rib with approved screws and neos alone (i. Design of Purlins and Sagrods Purlin length = Spacing of truss = 30 U 2. Stramit can supply lappable Zs, subject to inquiry, providing a unique section that offers strength and economy as well as a downturned lip. Our website is still under construction so if you don't see what you need listed yet then please call us at 866-811-5906 for other components and pricing. 2" O-C for a flat roof rafter and still meet code by me. Galvsteel™ is not recommended for use within 450mm of moist soil. Purlin Load Tables Simple Span Capacities 1. Table of C-Purlin. The load duration factor, C D, is 1. (the tables permit a bearing length of up to 3. Structural Z-Purlins, C-Purlins and custom shapes are available in a variety of sizes and gauges in lengths up to 30’. In each shape and size, a number of base steel thicknesses are available. Structural design of members subjected to loads or load combinations outside those covered by the span tables should be designed by appropriately. voestalpine Metsec are the UK’s largest designer & manufacturer of light gauge galvanised steel purlins, side rails and mezzanine floor systems. Would you be able to expand on how to read those tables? I can see the each span and the deflection measure but what is the meaning of. Please note that it is the spaced to meet speci˜c engineering. Lock When the bridging run terminates at a Zed purlin,the last intermediate bridging piece can be secured by applying a loose Lock. These purlins are commonly used in Pre-Fabricated Metal Buildings and in Solar Supports. Allowable working Loads ( kN/m2) Purlin Centres (mm). com offers 125 c purlin span tables products. Section properties and load span tables. ZED PURLIN SYSTEMS Z and C - sections For secondary steel structures Design tables according to Eurocodes Easy design in software MetSPEC 12 System solution Purlins and side rails • Eaves beams • Floor beams • Framing Large range of Z and C - sections. ) Spans are based on continuous lateral support of the compression flange. The loads have been based on the Standard AS/NZS 4600:1996 using Limit State method 2. • If posts are spaced further apart or snow load is greater than 25lb. If you did not know, you can have a steel home. STEEL JOIST SYSTEM FASTER LIGHTER EASIER High performance steel floor joist system Floor Joists "C" Purlin or 240x45x19 "I" Beam as per Engineering specification Perimeter Channel Web Penetration 300mm minimum Joist at support Joist at mid back span AN Telephone: +64 9 303 4825 Email: [email protected] This involves. 01 Design of Angle Purlin as Per is 800 (2007) Dr Ganesh Kame - Free download as Powerpoint Presentation (. Peter Falvey B. To know more call us at (02) 731-0000. C sections are not lapped together, for continuous spans they are end butted. Hi All Again in the vein of DIY home improvement, what size wood or steel (C or Z purlins) will span 6. Trusses are able to span further because of the ability to connect to both sides of Boxspan, which gives better torsional strength. In the example, the joists have a spacing of 16 inches and a span of 11 feet, 2 inches. The self weight of the section has not being deducted from the values below. Also we Hire!. Without a set of blueprints with a PE's seal, you have no option but to follow the inspectors gig. Purlin Spacing = 1. Strong and lightweight, our Z Purlins can span upwards of 25 feet depending on the roof load and the spacing of the Z Purlins. Generally C sections are used for simple span construction with the purlin butted at internal support. “Zee-Lock” (24 gauge Steel) Roof Panel attached to Steel Purlins Purlin Spacing Per Table "A" Purlins - 16 Gauge minimum Fastener: TWO Self-Drilling Screws Per Table "A" Typical at Each Purlin Zee-Rib Clip Zee Lock Panel Typical Roof Assembly Isometric View TABLE “A” METHOD 1 METHOD 2 METHOD 3 METHOD 4. Home » Products » Purlin Span Table - DORVIK STEEL SUPPLIES. 79196 GALv *. hitechsteelbuildings. ) Purlin Spacing: Refer to “TABLE A” Below Fastener spacing: Refer to “TABLE A” (along the purlin, in the valley of: Method 1: every third corrugation Method 2: every other corrugation) Sidelap spacing: 12” o. 0 LL ii) Span / 180 under unfactored imposed loads 1. LYSAGHT® Zed & Cee Purlins User Guide; NOTE: New South Wales designers must refer to the New South Wales LYSAGHT SupaZed® and LYSAGHT SupaCee® Purlins and Girts Range. C - Purlins are preferred for cladding as it gives a plane surface on one side. As per AS1684 and AS4055 SpanMan adopts a nett pressure coefficient applied along the full length of the purlin of Cpn -2. C&C Learn more about determining the best method of wind load analysis. They can not be lapped together, and instead when a continuous span is required they are end butted. L C P P U R L I N S & G I R T S® 2 INSTALLATION LCP C & Z sections are easily installed in single span, double span, Continuous Lapped and Reduced End Lap systems. Roof Framing: collar ties, rafter ties, tension beams & structural ridge beams: some of these can support the roof and prevent ridge sagging and wall spreading. Also used knee braces that cut the span down to16'. These purlins are fastened with two screws on each end and will ultimately have the roof metal screwed to them. Roof purlins are used for fastening metal roof panels. Bridging holes - C Purlins End holes - 35mm 0. I have a new home built with trusses and we are now getting drywall seam cracks in the ceiling. In cold rolled steel, any optimised desirable shaped can be used. C Purlins are horizontal structures that are used to support the load from the roof deck or the sheathing. Purlins Load Tables - Click Here. I'm assuming you're talking about C Purlin rather than. All uplift values are based on a minimum of a 3-span or 4-span. For outwards loads on equal continuous spans the. Scheme development: Purlin structure design SS049a-EN-EU provide tables for determining their maximum span length (and thus the maximum spacing between purlins) depending on the span length load. Purlins & Framing. When one purlin is rotated 180 0 two sections can be bolted. The purlin is manufactured applying to international industry standards G240 MPA/G340 MPA/G550 MPA, Z 120 GSM/Z 275 GSM & Z 180 GSM. All cut to length and in a range of depths. Where span variations are unavoidable the most robust structure will result if the larger spans are kept away from the end bay locations. STEP FOUR. We are able to roll the z purlins with the small lips (d) at 90 degrees or as the picture below shows at 145 degrees, the latter can be lapped so eliminating the need for purlin sleeves. There are many different types of C Purlins | Metal Buildings Oklahoma that you can find from Mid-America and make into a kit. These can also be used on multi bay buildings in lines of simple spanning purlins and girts. Don’t be afraid to go to use a shorter span if you are unsure. How do I calculate rafter size with purlin bracing? The total span is ~23' and the purlin bracing is ~9' from one side and ~14' from the other. SupaPurlin - Analysis and Design of Supa Purlins According to AS/NZS 4600. Any body point me in the right direction for span tables for steel c purlins. "C" Purlin or "I" Beam as per Engineering specification Perimeter Channel Web Penetration 300mm minimum Joist at support Joist at mid back span AN Telephone: 1300 66 77 67 or 0410 442744 Email: [email protected] E) DEFLECTION LIMITS The deflection limits under serviceability loads shall not exceed the followings : i) Span / 150 under loads combination 1. You can also choose from not perforated, is perforated. Yes I admit that a 2x6 layed on it's side will not span 8'. C – Purlin gives similar advantages as Z – Purlin. All input values must be metric. 4" deflection. Pitched roof timber sizes. Dead Load 15. It is not a mid-span sorta-kinda support. As a result, improvements on the most commonly used steel purlins are achieved, by substituting some of the steel sections for wooden sections. In some large roof structures such as indoor or outdoor sports stadiums the rafter depth may exceed 2m. We manufacture and supply C purlin, Z purlin and Top Hat sections that have greater corrosion resistance and last longer under extreme weather conditions. Rake angles, hip and valley covers must be installed on top of the purlins prior to installing the MAC 200 panels. The vertical loads. Example 2 Select the lightest 8-inch deep, simply supported ERW HSS beam of Fy = 50 ksi (ASTM A500 Gr. Limit State Capacity tables for different purlin configurations can be found in the user manual. Galvanized Metal Purlins and Red Prime Painted Metal Purlins. 1 1098] Compute resulting uniform wind load 1 -19. We manufacture any component from 1/2" steel subgirts to 12" section up to 10 gauge. It's best if you allow the space under the dressing table to be vacant to make a light and airy feeling. These purlins are commonly used in Pre-Fabricated Metal Buildings and in Solar Supports. purlin sections : c sections. 6 Purlins supporting rafters. Heel joint connections are not required where the ridge is supported by a load-bearing wall, header or ridge beam. Don’t be afraid to go to use a shorter span if you are unsure. Station C&Z Purlins section are shown in Table 1: Adverse Conditions Design Station C&Z Purlins and Girts will give excellent durability in most applications. The steel c purlins are in turn supported by rafters or walls. When one purlin is rotated 1800 two sections can be bolted together enabling them to be lapped. 1 of ASCE 7-10 for the applicable load combinations using Allowable Stress Design. au website or speak with Spantec’s Technical department. Dead Load 15. They're resistant to bacteria, humidity, stains, mould, crack, and processor. SupaPurlin - Analysis and Design of Supa Purlins According to AS/NZS 4600. 2" or 24" on-center spacing. Continuous Purlin Span. This assembly video shows a DIY approach to assembling the Centra Series metal building. Cee Purlin is primarily used as structural framework in buildings due to its lightweight and economical properties. The main difference between these types is that the C sections have flanges that are equal in size. [2] Simple span only; minimum end bearing length is 2 ¼. You can mix any components to make a load. 3) For design parameters, refer to figure 6. Manufactured for reliable performance, straight and true hySPAN LVL provides predictable and consistent performance. In this section you'll find sample calculations for determining wind and snow loads as well as Z purlin and Z girt weight tables. 0 LL ii) Span / 180 under unfactored imposed loads 1. Zee Purlin Span Tables. 12 Example C Purlin Span Chart. C AND Z SPAN LOAD TABLE: Z PURLIN AND GIRT SECTION PROPERTIES. L C P P U R L I N S & G I R T S® 2 INSTALLATION LCP C & Z sections are easily installed in single span, double span, Continuous Lapped and Reduced End Lap systems. The steel c purlins are in turn supported by rafters or walls. It is not feasible to provide span tables for all load cases and combinations. 572m) length. Span Calculator for Wood Joists and Rafters also available for the Android OS. There's plenty of reasons why you should ask for GALVASPAN® steel when specifying or ordering purlins and girts. Cee Purlin is primarily used as structural framework in buildings due to its lightweight and economical properties. Young’s Modulus = 200 GPa. Galvanised hi-tensile steel is not recommended for use within 450mm of moist soil. This content is written for MiddleAmericaSteel. Compliant with section J of the BCA. It refers to unequal flange Zees only Nominal Size Actual Size* Gauge Weight Per LF 4 x 2 4 x 2 16 1. Purlin spacing is dependent on profile of the metal and gaugeplus snow and wind load, plus what the rafters are designed to carry. Span tables allow users to choose an appropriate size and stress grade to achieve spanning needs. Local buckling is common in the web and the flange of the purlin section. The attic does have ventilation from the soffit vents and ridge vent, the same with the back roof. purlin sections : c sections. no washer) D Fixed every purlin at side laps and every alternate rib with approved screws and neos and load spreading profile metal washers and EPDM Washers. You can use SBCA’s span charts to roughly determine truss sizes available. This is acheived by reducing the plane of the purlins sufficiently for each sheet run to overlap the next. We are pleased to offer truckload pricing throughout the South Eastern United States. Unwashed areas subject to salt-laden air or other corrosive matter may need additional protection. Purlins span from truss to truss and serve basically the same purpose as joists do. C Section Purlins C Section Purlins are generally manufactured from GALVASPAN® steel and are roll formed into C Section. My table shows a 5" x 3" 10. All uplift values are based on a minimum of a 3-span or 4-span. for foundation walls-crawlspace or basements). Code D B L t x Area lm/ tonne Z100-15 102 53 49 13. L L † D B C PURLIN proFilE CodE proFilE dESCription d (MM) B (MM) l (MM) gAugE (MM) SECtion ArEA (MM²) kg pEr M MAtEriAl dESCription SpECiAl notE tp10010 100x51x15x1. For screw size range and fastener / washer assembly refer Section 2. These are available in a choice of systems to suit virtually any requirement in terms of span, load, complexity or preferred site practice:. C – Purlin gives similar advantages as Z – Purlin. The Stratco Rapidfix bridging system is suitable for use with the Maxi-Purlin range with further details available from the 'Stratco Purlins & Girts Capacity Tables. KFC Roofing Supplies C & Z Style Purlins - Stramit Exacta® C & Z Purlins & GirtsStramit Exacta® C&Z Purlins come in sizes of 150, 200, 250, 300 and 350 are subtly but importantly different to standard Stramit® Z&C Purlins. Values do not address the strength of the fastener/purlin connection. Alfa is the leading manufacturers & suppliers of GI Metal Decking Sheets, Roof Decking Sheet, Metal Decking Sheets, Steel Deck Sheet, GI Coated Decking Sheet. Phoenix Steels offer a complete range of Purlins including Z Purlins, C Purlins and Eaves Beams. So if the span of the rafter is within the allowable limits no purlin is needed. PURLIN SPAN (mm) MAX. Canam Canada fabricates a complete range of C and Z sections for use as purlins and girts at its plant in Boucherville, Quebec. However if either of the above conditions are not met, use the single span tables for the. hitechsteelbuildings. where the purlins are set within the depth of the rafter. 4mm steel, 0. discussion on the TexAgs Outdoors forum. And make it big enough to hold up the load over the span between rafters. Longer spans are accomplished. 79196 GALv *. c350-32h c300-32h c300-25h c250-25h c250-24l c250-20h. Its shape allows the purlin to overlap with others at the joints. I used 8"x2. The ProSigma+ range is a series of purlins and rails suitable for use in industrial, commercial and agricultural applications. AEP Span's concealed fastener Span-Lok™ hp is a performance-rated architectural standing seam metal roof system that has a mechanically seamed 2″ high rib, providing aesthetic appeal and. About 78% of these are steel channels, 10% are metal building materials, and 6% are steel structures. C Purlin - Cee or C purlins are shaped like a squared-off letter C. All purlins and girts are cold-formed using high-performance steel in order to minimize weight while maximizing capacity. Z PURLINS: Z sections are made with one flange broader than the other. 2m wide (from centre of garage to right side of garage), X 2. For Continuous Lapped and Reduced End Lap systems,. At a single span of 4. This involves. Safe roof purlins spans appendix b properties of cold formed girts and purlins z purlin span tables our products steel purlins span table car interior design z purlin tables. Get a fast quote on the Z Purlins, for Roof Secondary Systems (Purlins and Eave Members) at Butler Parts Online. Pitched roof timber sizes. purlins and girts in a much wider range of spanning and bridging configurations than before. PURLIN - Analysis and Design of Cold-Formed Purlins According to AS/NZS 4600. These tables are for spans in which purlins are lapped over each support, where the lap length is 15% of the span. Large Span Lattice Frame Industrial Roof Structure DOI: 10. FYI, we run purlins on 3 - 5 feet on center, depending on size of purlin. It is not feasible to provide span tables for all load cases and combinations. Our range purlins are light in weight and perfect for simple span. Quality Tanalised Timber Purlins. Sizes: C10010 - C40030. Steel purlins span table car interior design tong yong metal panels structural metals sacramento c purlin roofing steel product kextra malaysia. Economical Span Configurations 4 Design Data 5 Sizes 5 Section Properties 6-8 Suspended Loads 8 Local Pressure Zones 8 Purlin Spacing 9 Span Configurations 9 Capacities 9 Design Capacity Tables 10-23 Design Rules/Assumptions 22-23 Bridging Positions 24 Girt Bridging Capacity 24-26 Laps 26 Bolts 26 Holes 26 Fascia Purlins 26 Cantilevers 26 R. Technical details and dimensions of Metsec c purlins. 6mm in steel*. We doesn't provide steel c channel span tables products or service, please contact them directly and verify their companies info carefully. Learn more about Kingspan Group. Cleveland SIPS Technical Services team is available to help with specification questions. Machine adopt cast iron structure, which will increase the strength of the machine. We are the leading expert in Vietnam in designing, making, installing all kinds of roll forming, bending, cutting, and punching machines, etc…such as:. Purlins Load Tables – Click Here. x 10" anchor bolts @ 6'-0" O. Quality Cold Roll Forming Machine manufacturers & exporter - buy Single Side Auto Adjustable C Purlin Cold Roll Forming Machine TW-C300 from China manufacturer. The fixing of the purlins to the. STEP THREE Adjust all Hangers to correct drop using string line or laser. Deflection Limit = Span/150 (IS 800 – 2007). Formed channels, Cs and Zs used as purlins and girts. lips while the “C” sections use 90-degree lips. two-span purlin but with only one span exposed to fire. TRADA Document – ‘Span tables for solid timber Building Control Guidance Note 18 - Purlin and Rafter Roofs - Timber Sizes and Construction Details. We deliver Metro Area! Have a look at our great prices on new products. C PURLINS: C sections have flanges which are equal in size and are commonly used for simple supported spans. Manufactured from high tensile galvanised steel they accommodate C Purlins from 100-250mm web height. ***Maximum Span (m) of joists at Nominated Spacing (mm) for 5kPa floor live load typical for Industrial applications. on the building, lapped at the supports to develop a structurally efficient continuous beam across multiple supports. 39 Varies End bay distance 35 mm CLEATS Holing Details Only 18mm dia. This is based upon the span of the rafter (horizontal span, not total rafter length), live and dead loads. C purlins are often favoured for their stability in single spans and are also adaptable to doubly symmetric "I" and "box" configurations. Max-Span PURLIN – Analysis and Design of Max-Span Purlins to AS/NZS 4600. Unwashed areas subject to salt-laden air or other corrosive matter may need additional protection. (mm) WIND ZONE L M H VH EH HEAVY ROOF Tile Battens 900 370 A A A A A LIGHT ROOF Tile Battens 900 370 A A B C C 1200 370 A B C C C LIGHT ROOF Purlins 900 900 C C C C D 1200 900 C C C D D 1200 1200 C C D E E Wind Zone: As per NZS 3604:2011 L = Low Wind M = Medium Wind H = High Wind VH = Very High Wind EH = Extra. Route trucks servicing the entire country. Z Purlin - The zee or Z purlin is shaped like a letter Z. Your local code officials can show you a rafter span table that applies to your area. The Stratco Maxi-Purlin Z & C sections range from 150mm through to 350mm in depth and design capacity tables have been generated for a comprehensive range of span configurations. increase for a 16-gauge purlin). Manufactured from high tensile galvanised steel they accommodate C Purlins from 100-250mm web height. Applications of c & z purlin including : Industrial construction. (unpunched) * All other Purlins are ordered in from our supplier Bluescope Lysaght,and are subject to a rolling schedule. Refer to Figures 3 & 7 for information on positioning of Hangers, Top Cross Rail and Wall Track. You are looking at a pretty massive beam to carry any 20' span. Mezzanine floor, 4. The content on this page will explain how to interpret the results from the calculator. Engineering span and load tables are available for all Products; For more complex requirements we have an in house R&D team to design products. 6 applied to the interior uplift reaction. They are loaded with a surface load of width L1=0. The following table provides the maximum spans for Maxilite, in all the grades such as clear, HG and FG for each profile and sheet thickness limited by the ultimate limit state capacities given. Get a price for Trapezoidal Roof Decking Sheet Profile. AEP Span's concealed fastener Span-Lok™ hp is a performance-rated architectural standing seam metal roof system that has a mechanically seamed 2″ high rib, providing aesthetic appeal and. c350-32h c300-32h c300-25h c250-25h c250-24l c250-20h. The garage is constructed of 150mm C Purlins. L L † D B C PURLIN proFilE CodE proFilE dESCription d (MM) B (MM) l (MM) gAugE (MM) SECtion ArEA (MM²) kg pEr M MAtEriAl dESCription SpECiAl notE tp10010 100x51x15x1. I'd much rather use the C Purlins as they are considerably cheaper but will they support the 3 meter span. 6m C/20015 FASCIA PURLIN REFER TABLE up to & inc C250 and Above 8. Purlins span tables table2 rafter spans c24 strength class timber table1 flat roof joists for walking on strength grade c24 timber table6 joist span tables. Goto Top Purlins - View all ads available in the Philippines - OLX. Get a quote today. - These span tables are only for use in conjunction. Also, the modification included the addition that, "For continuous purlin systems in which adjacent bay span lengths vary by more than 20%, for the adjacent bays the 'R' value shall be taken from Table C3. C Purlin - Cee or C purlins are shaped like a squared-off letter C. 5 is probably the worst case that you’ll encounter for joist or rafter bearing, it’s a safe value. We are pleased to offer truckload pricing throughout the South Eastern United States. Depending on loads and spans, C-Joists are typically spaced at 12", 16", 19. 2m wide (from centre of garage to right side of garage), X 2. Purlins are installed horizontally. Applications of c & z purlin including : Industrial construction. 3) For design parameters, refer to figure 6. Choose from Australian steel sections, UNIVERSAL BEAMS, PARALLEL FLANGE CHANNEL, UNIVERSAL COLUMNS, and Z/C PURLINS. Mohammad Barqawi. North American approach to the design of continuous Z-and C- purlins for gravity loading with experimental verification Thomas M. Lapped continuous spans result in considerable capacity increase in the system. span tables. C and Z Purlins. Capacities are total uniformly distributed load which can be supported by the section in the absence of axial load. B) ROOF PITCH The Purlin Selection Table is applicable for roof pitch ≤ 30 ° C) SUPPORT CONDITION The purlin is simply supported with pinned joints over supports. Chapter 6 Structures Part 650 Engineering Field Handbook Florida Supplement (210-vi-EFH-Florida Supplement March, 2011) FL6-A-3 Figure 1. C sections are used primarily for cladding rails and secondary floor joists. AEP Span's concealed fastener Span-Lok™ hp is a performance-rated architectural standing seam metal roof system that has a mechanically seamed 2″ high rib, providing aesthetic appeal and. Showing results for Purlins & Framing products for All Suppliers Product availability varies by state and supplier. In steel construction, the term purlin typically refers to roof framing members that span parallel to the building eave and support the roof decking or sheeting. ASCE/SEI 7-10, Minimum Design Loads of Buildings and Other Structures, lists two methods for calculating wind pressures: Main Wind Force Resisting System (MWFRS) and Components & Cladding (C&C). Deflection is limited to the span in inches divided by 360, 240 or 180 and is based on live load only. Longer spans are accomplished. BRIDGING. Post Size- 6 x 8 pressure treated (PT) for ground contact. 5 psf, Sagrods + Bracings = 1 psf Basic Wind Speed V = 120 mph Material Properties: f c = 3 ksi, f y = 40 ksi 1. This involves. The model is composed of steel purlin, steel console and steel sheeting, which is used to simulate the inner plate of the sandwich. c purlin span. Structural applications include portal frames, roofing, single bay buildings, wall cladding and flooring systems. The ProSigma+ range is a series of purlins and rails suitable for use in industrial, commercial and agricultural applications. L C P P U R L I N S & G I R T S® 2 INSTALLATION LCP C & Z sections are easily installed in single span, double span, Continuous Lapped and Reduced End Lap systems. Two basic cold formed section C & Z are available. The solutions provided may be conservative, but can be. double-span sections. Re: 4" C Purlin Span This is a little off topic from this thread, but I thought that someone might be able to help. Trusses are able to span further because of the ability to connect to both sides of Boxspan, which gives better torsional strength. 2 for the design of buildings in cyclonic areas. CanAm Steel Building Corporation cee's, zee's and eave struts are available in stock or custom lengths, 16 gauge through 12 gauge material. One Part Splices Purlins and Receives Shore! Here is the simplified way to do two jobs at once in shoring: Nailed to adjoining ends of two purlins, it is a splicerâ⠬¦with a shore slipped into the bottom part, it is a shore holder!. The span tables have been calculated in accordance with the principles of structural mechanics using the following. increase for a 16-gauge purlin). We offer solution of cold roll formed C – Purlin in Lip, it is also called C lip Channel. Galvanizing the steel increases its corrosion-resistance. Metal C Purlins are light in weight and perfect for simple span construction. 6 Purlins supporting rafters. 35 Simple connection 0. Our C and Z purlin prices are competitive and our quality is excellent. Where span variations are unavoidable the most robust structure will result if the larger spans are kept away from the end bay locations. Cee Purlin is primarily used as structural framework in buildings due to its lightweight and economical properties. There are three types of purlins in wood construction: Purlin plates (Under purlin), Principal purlins and Common purlins. Figure 13‐Connection between rafter section and purlins Figure 14‐Purlin cross‐section (Kingspan) Purlin Rafter. Composite Beam * Tables relate to single span floors. L L † D B C PURLIN proFilE CodE proFilE dESCription d (MM) B (MM) l (MM) gAugE (MM) SECtion ArEA (MM²) kg pEr M MAtEriAl dESCription SpECiAl notE tp10010 100x51x15x1. C Purlin and C Girt Structural Steel Wind, Snow, & Weight Tables. Z Purlin - The zee or Z purlin is shaped like a letter Z. Gauge of the material to be determined by the project engineer. Post Height- Max. Downturn Lips All Stramit® Purlins,both Z and C profiles,can be supplied. Get a quote today. Perimeter Channels to be fixed every 600mm with 2 x M12 bolts and washers to C Purlin Joist Span Composite 1. 004KN/m2, the M175065120 section seems adequate. I am needing to weld some more purlins in there to span this 10' gap and to attach the floor to. The Stratco Rapidfix bridging system is suitable for use with the Maxi-Purlin range with further details available from the ‘Stratco Purlins & Girts Capacity Tables. STEEL PURLIN "C" RED OXIDE. Gypsum Deck Plank: 1. The span of Vertical C is the wall height (less the sole plate and header vertical dimensions). teel Joist Span Tables are to be utilized in conjunction with the notes below. It comprises 7 section depths in 3 separate material thicknesses as outlined below. The building must be squared according to accepted building practices. All other data is available on page 121 of the 2012 International Residential Code. Set the purlins on the chalk line, pre-drill the holes and secure with galvanized wood screws. ) Purlin Spacing: Refer to “TABLE A” Below Fastener spacing: Refer to “TABLE A” (along the purlin, in the valley of: Method 1: every third corrugation Method 2: every other corrugation) Sidelap spacing: 12” o. SPAN TABLES - These span tables have been developed in good faith, with the assistance of Mr. c purlins supplier philippines. S pan Table Notes: 1. 3) For Vertical D, the Load Width for Vertical D is LW 7, OR; ½ HD 3 + ½ HD 4. The Stramit Exacta C and Z purlins and girts are manufactured from hi-tensile Galvaspan steel and can be coated in a range of options including ZAM coating technology. A purlin is used to “reduce the length of the rafter”. 01 Design of Angle Purlin as Per is 800 (2007) Dr Ganesh Kame. NOTE: These tables to be used as a guide only. KFC Roofing Supplies C & Z Style Purlins - Stramit Exacta® C & Z Purlins & GirtsStramit Exacta® C&Z Purlins come in sizes of 150, 200, 250, 300 and 350 are subtly but importantly different to standard Stramit® Z&C Purlins. across the row at the span equal to 22 feet and note that the maximum factored uniform load is equal to 167 kips. t Load Span Tables Based on Working Stress and attached to each purlin, 2’ on center. Z PURLINS: Z sections are made with one flange broader than the other. As has been mentioned, there is simply no way an 8x8 is going to carry 20', even carrying its own weight. It is intended that these tables will be used by Engineers to assist in the preliminary design of a composite steel and concrete floor system. Here are some pictures of C purlin forming machine C Purlin Forming Machine can produce many standards of C Purlin. metl-span® details must be followed as a minimum to ensure appropriate warranties will be issued. 2, Assuming less than 5% openings Design Wind Force on Purlin Section = (Cpe + Cpi) * Pz * c/c Distance Between the Purlins 6. DETERMINE UNIFORM LIVE LOAD Reference BOCA, Table 1607. LaBoube2, Thomas M.